Virdi Electric Works Private Limited
Virdi Electric Works Private Limited
Gautam Budh Nagar, Uttar Pradesh
GST No. 09AACCV2089H1Z2
TrustSEAL Verified
Call 0804898927681% Response Rate
SEND EMAIL

New Item

We manufacture a range of air cool machines, transformers, stabilizers and welders. Our range includes:

Three Phase 25 Kva Distribution Transformer

Three Phase 25 Kva Distribution Transformer
  • Three Phase 25 Kva Distribution Transformer
Get Best Quote
Approx. Price: Rs 58,000 / PieceGet Latest Price

Product Details:

Power Rating25 KVA
Number of Phase3-Phase
Voltage Ratio11kV/433V
Cooling TypeONAN
Winding MaterialCopper
Phase3-Phase
StandardsIS-1180
BrandVirdi

The main process lines of the transformers are:

Core:
The core is made with laminated and low loss electrical steel sheets that are imported, grain oriented, cold rolled and sheets of high-grade steel. The cores are assembled in a manner that they reduce the noise caused by vibration; individual stamping is coated with insulation varnish which is resistant to heat and oil on both sides. The core is connected to the clamp which ensures that it is effectually earthed. The core legs are bounded with heavy-duty insulating tape. The yokes are rigidly and securely clamped between the folded steel channels. Clamps on top and bottom are firmly attached to each other by the means of tie rods. Tie rods serves the duel purpose of transferring the load from the bottom to the top clamps and securing the winding in place. This prevents tensile stress being setup in the core legs, which could adversely affect the iron losses.

Winding:
Transformer windings also known as 'Coils' are precisely designed to meet three basic requirements: thermal, mechanical and electrical. These windings wound concentrically and are cylinder shaped. Both H.V. L.V. type windings are wound with adequate securing and brazing tapes in order to get a sturdy, robust and self-supporting structure. It is provided with inter layer ducts which ensure low-temperature gradient between windings and oil so the hot spot temperature is kept to the minimum. This guarantees that the rate of insulation deterioration is lowered to attain high life expectancy.

Winding Connections:
Tapping and phase lead run in paper covered conductors. Adequate barriers are used to separate the phase leads from the tapping. Rigidly brazed tubes are used to maintain the required clearance from the coil to tank.
LV Leads, larger in cross-section, are usually sturdy and robust, where necessary supports are provided.

Insulation And Impregnation:
The principal component of insulation is insulating pre-compressed pressboard. The component like ring ducts dovetailed spacer; blocks etc. are put under compressing along with the coil assembly for preshrinking. The slight recovery in dimension after the preshrinking is compensated by providing additional insulation. This reduced the probability if coils getting loose during operation and also minimize the failure due to short circuit forces.

Short Circuit Capability:
In the order to prevent deformation under short-circuit forces; solid insulation end block and ring are used. Winding are compressed under top and bottom clamping members with the help of tie rods. The axial end thrust under fault conditions is minimized by the suitable balance of the ampere-turns over the length of windings. In a case of the bigger transformer, the HV tapping leads are taken out from two positions to balance the short-circuit forces in a much better way.

Tank Construction:
All tank are made from mild steel sheet of adequate thickness with corrugated wall panel type radiators of pressed steel fin/cooling tube for heat dissipation.
All tanks are checked by magma flux, ultraviolet ray dies penetrating system to ensure that there is absolutely no leakage from any part of the tank.

Quality Finish Through Use Of Shotblasting Technology:
Tanks are shot blasted to remove mill and welding scale and then a primer coat is immediately applied to the exterior to eliminate rust formation.
After priming, all tanks receive a coat of intermediate paint and after pressure testing; they receive a final coat of high gloss paint applied by spray. This ensures high coverage helping to combat corrosion in an inaccessible place.
Request
Callback
Products & Services

Distribution Transformer 1600 Kva

Distribution Transformer 1600 Kva
  • Distribution Transformer 1600 Kva
Get Best Quote
Approx. Price: Rs 17.25 Lakh / PieceGet Latest Price

Product Details:

Power Rating1600 KVA
Number of Phase3-Phase
Voltage Ratio11kV/433V
Cooling TypeONAN
Winding MaterialCopper
StandardsIS-1180
BrandVirdi

The main process lines of the transformers are:

Core:
The core is made with laminated and low loss electrical steel sheets that are imported, grain oriented, cold rolled and sheets of high-grade steel. The cores are assembled in a manner that they reduce the noise caused by vibration; individual stamping is coated with insulation varnish which is resistant to heat and oil on both sides. The core is connected to the clamp which ensures that it is effectually earthed. The core legs are bounded with heavy-duty insulating tape. The yokes are rigidly and securely clamped between the folded steel channels. Clamps on top and bottom are firmly attached to each other by the means of tie rods. Tie rods serves the duel purpose of transferring the load from the bottom to the top clamps and securing the winding in place. This prevents tensile stress being setup in the core legs, which could adversely affect the iron losses.

Winding:
Transformer windings also known as 'Coils' are precisely designed to meet three basic requirements: thermal, mechanical and electrical. These windings wound concentrically and are cylinder shaped. Both H.V. L.V. type windings are wound with adequate securing and brazing tapes in order to get a sturdy, robust and self-supporting structure. It is provided with inter layer ducts which ensure low-temperature gradient between windings and oil so the hot spot temperature is kept to the minimum. This guarantees that the rate of insulation deterioration is lowered to attain high life expectancy.

Winding Connections:
Tapping and phase lead run in paper covered conductors. Adequate barriers are used to separate the phase leads from the tapping. Rigidly brazed tubes are used to maintain the required clearance from the coil to tank.
LV Leads, larger in cross-section, are usually sturdy and robust, where necessary supports are provided.

Insulation And Impregnation:
The principal component of insulation is insulating pre-compressed pressboard. The component like ring ducts dovetailed spacer; blocks etc. are put under compressing along with the coil assembly for preshrinking. The slight recovery in dimension after the preshrinking is compensated by providing additional insulation. This reduced the probability if coils getting loose during operation and also minimize the failure due to short circuit forces.

Short Circuit Capability:
In the order to prevent deformation under short-circuit forces; solid insulation end block and ring are used. Winding are compressed under top and bottom clamping members with the help of tie rods. The axial end thrust under fault conditions is minimized by the suitable balance of the ampere-turns over the length of windings. In a case of the bigger transformer, the HV tapping leads are taken out from two positions to balance the short-circuit forces in a much better way.

Tank Construction:
All tank are made from mild steel sheet of adequate thickness with corrugated wall panel type radiators of pressed steel fin/cooling tube for heat dissipation.
All tanks are checked by magma flux, ultraviolet ray dies penetrating system to ensure that there is absolutely no leakage from any part of the tank.

Quality Finish Through Use Of Shotblasting Technology:
Tanks are shot blasted to remove mill and welding scale and then a primer coat is immediately applied to the exterior to eliminate rust formation.
After priming, all tanks receive a coat of intermediate paint and after pressure testing; they receive a final coat of high gloss paint applied by spray. This ensures high coverage helping to combat corrosion in an inaccessible place.
Request
Callback
Products & Services

630 Kva Distribution Transformer

630 Kva Distribution Transformer
  • 630 Kva Distribution Transformer
Get Best Quote
Approx. Price: Rs 7.85 Lakh / PieceGet Latest Price

Product Details:

Power Rating630kVA
Number of Phase3-Phase
Voltage Ratio11kV/433V
Cooling TypeONAN
Winding MaterialCopper
StandardsIS-1180
BrandVirdi

The main process lines of the transformers are:

Core:
The core is made with laminated and low loss electrical steel sheets that are imported, grain oriented, cold rolled and sheets of high-grade steel. The cores are assembled in a manner that they reduce the noise caused by vibration; individual stamping is coated with insulation varnish which is resistant to heat and oil on both sides. The core is connected to the clamp which ensures that it is effectually earthed. The core legs are bounded with heavy-duty insulating tape. The yokes are rigidly and securely clamped between the folded steel channels. Clamps on top and bottom are firmly attached to each other by the means of tie rods. Tie rods serves the duel purpose of transferring the load from the bottom to the top clamps and securing the winding in place. This prevents tensile stress being setup in the core legs, which could adversely affect the iron losses.

Winding:
Transformer windings also known as 'Coils' are precisely designed to meet three basic requirements: thermal, mechanical and electrical. These windings wound concentrically and are cylinder shaped. Both H.V. L.V. type windings are wound with adequate securing and brazing tapes in order to get a sturdy, robust and self-supporting structure. It is provided with inter layer ducts which ensure low-temperature gradient between windings and oil so the hot spot temperature is kept to the minimum. This guarantees that the rate of insulation deterioration is lowered to attain high life expectancy.

Winding Connections:
Tapping and phase lead run in paper covered conductors. Adequate barriers are used to separate the phase leads from the tapping. Rigidly brazed tubes are used to maintain the required clearance from the coil to tank.
LV Leads, larger in cross-section, are usually sturdy and robust, where necessary supports are provided.

Insulation And Impregnation:
The principal component of insulation is insulating pre-compressed pressboard. The component like ring ducts dovetailed spacer; blocks etc. are put under compressing along with the coil assembly for preshrinking. The slight recovery in dimension after the preshrinking is compensated by providing additional insulation. This reduced the probability if coils getting loose during operation and also minimize the failure due to short circuit forces.

Short Circuit Capability:
In the order to prevent deformation under short-circuit forces; solid insulation end block and ring are used. Winding are compressed under top and bottom clamping members with the help of tie rods. The axial end thrust under fault conditions is minimized by the suitable balance of the ampere-turns over the length of windings. In a case of the bigger transformer, the HV tapping leads are taken out from two positions to balance the short-circuit forces in a much better way.

Tank Construction:
All tank are made from mild steel sheet of adequate thickness with corrugated wall panel type radiators of pressed steel fin/cooling tube for heat dissipation.
All tanks are checked by magma flux, ultraviolet ray dies penetrating system to ensure that there is absolutely no leakage from any part of the tank.

Quality Finish Through Use Of Shotblasting Technology:
Tanks are shot blasted to remove mill and welding scale and then a primer coat is immediately applied to the exterior to eliminate rust formation.
After priming, all tanks receive a coat of intermediate paint and after pressure testing; they receive a final coat of high gloss paint applied by spray. This ensures high coverage helping to combat corrosion in an inaccessible place.
Request
Callback
Products & Services

Distribution Transformer 160kva

Distribution Transformer 160kva
  • Distribution Transformer 160kva
Get Best Quote
Approx. Price: Rs 2.55 Lakh / PieceGet Latest Price

Product Details:

Power Rating160kVA
Number of Phase3-Phase
Voltage Ratio11kV/433V
Cooling TypeONAN
Winding MaterialCopper
StandardsIS-1180
BrandVirdi

The main process lines of the transformers are:

Core:
The core is made with laminated and low loss electrical steel sheets that are imported, grain oriented, cold rolled and sheets of high-grade steel. The cores are assembled in a manner that they reduce the noise caused by vibration; individual stamping is coated with insulation varnish which is resistant to heat and oil on both sides. The core is connected to the clamp which ensures that it is effectually earthed. The core legs are bounded with heavy-duty insulating tape. The yokes are rigidly and securely clamped between the folded steel channels. Clamps on top and bottom are firmly attached to each other by the means of tie rods. Tie rods serves the duel purpose of transferring the load from the bottom to the top clamps and securing the winding in place. This prevents tensile stress being setup in the core legs, which could adversely affect the iron losses.

Winding:
Transformer windings also known as 'Coils' are precisely designed to meet three basic requirements: thermal, mechanical and electrical. These windings wound concentrically and are cylinder shaped. Both H.V. L.V. type windings are wound with adequate securing and brazing tapes in order to get a sturdy, robust and self-supporting structure. It is provided with inter layer ducts which ensure low-temperature gradient between windings and oil so the hot spot temperature is kept to the minimum. This guarantees that the rate of insulation deterioration is lowered to attain high life expectancy.

Winding Connections:
Tapping and phase lead run in paper covered conductors. Adequate barriers are used to separate the phase leads from the tapping. Rigidly brazed tubes are used to maintain the required clearance from the coil to tank.
LV Leads, larger in cross-section, are usually sturdy and robust, where necessary supports are provided.

Insulation And Impregnation:
The principal component of insulation is insulating pre-compressed pressboard. The component like ring ducts dovetailed spacer; blocks etc. are put under compressing along with the coil assembly for preshrinking. The slight recovery in dimension after the preshrinking is compensated by providing additional insulation. This reduced the probability if coils getting loose during operation and also minimize the failure due to short circuit forces.

Short Circuit Capability:
In the order to prevent deformation under short-circuit forces; solid insulation end block and ring are used. Winding are compressed under top and bottom clamping members with the help of tie rods. The axial end thrust under fault conditions is minimized by the suitable balance of the ampere-turns over the length of windings. In a case of the bigger transformer, the HV tapping leads are taken out from two positions to balance the short-circuit forces in a much better way.

Tank Construction:
All tank are made from mild steel sheet of adequate thickness with corrugated wall panel type radiators of pressed steel fin/cooling tube for heat dissipation.
All tanks are checked by magma flux, ultraviolet ray dies penetrating system to ensure that there is absolutely no leakage from any part of the tank.

Quality Finish Through Use Of Shotblasting Technology:
Tanks are shot blasted to remove mill and welding scale and then a primer coat is immediately applied to the exterior to eliminate rust formation.
After priming, all tanks receive a coat of intermediate paint and after pressure testing; they receive a final coat of high gloss paint applied by spray. This ensures high coverage helping to combat corrosion in an inaccessible place.
Request
Callback
Products & Services

100 Kva Distribution Transformer

100 Kva Distribution Transformer
  • 100 Kva Distribution Transformer
Get Best Quote
Approx. Price: Rs 1.65 Lakh / PieceGet Latest Price

Product Details:

Power Rating100 KVA
Number of Phase3-Phase
Voltage Ratio11kV/433V
Cooling TypeOil Cooled
Winding MaterialCopper
StandardsIS-1180
BrandVirdi

The main process lines of the transformers are:

Core:
The core is made with laminated and low loss electrical steel sheets that are imported, grain oriented, cold rolled and sheets of high-grade steel. The cores are assembled in a manner that they reduce the noise caused by vibration; individual stamping is coated with insulation varnish which is resistant to heat and oil on both sides. The core is connected to the clamp which ensures that it is effectually earthed. The core legs are bounded with heavy-duty insulating tape. The yokes are rigidly and securely clamped between the folded steel channels. Clamps on top and bottom are firmly attached to each other by the means of tie rods. Tie rods serves the duel purpose of transferring the load from the bottom to the top clamps and securing the winding in place. This prevents tensile stress being setup in the core legs, which could adversely affect the iron losses.

Winding:
Transformer windings also known as 'Coils' are precisely designed to meet three basic requirements: thermal, mechanical and electrical. These windings wound concentrically and are cylinder shaped. Both H.V. L.V. type windings are wound with adequate securing and brazing tapes in order to get a sturdy, robust and self-supporting structure. It is provided with inter layer ducts which ensure low-temperature gradient between windings and oil so the hot spot temperature is kept to the minimum. This guarantees that the rate of insulation deterioration is lowered to attain high life expectancy.

Winding Connections:
Tapping and phase lead run in paper covered conductors. Adequate barriers are used to separate the phase leads from the tapping. Rigidly brazed tubes are used to maintain the required clearance from the coil to tank.
LV Leads, larger in cross-section, are usually sturdy and robust, where necessary supports are provided.

Insulation And Impregnation:
The principal component of insulation is insulating pre-compressed pressboard. The component like ring ducts dovetailed spacer; blocks etc. are put under compressing along with the coil assembly for preshrinking. The slight recovery in dimension after the preshrinking is compensated by providing additional insulation. This reduced the probability if coils getting loose during operation and also minimize the failure due to short circuit forces.

Short Circuit Capability:
In the order to prevent deformation under short-circuit forces; solid insulation end block and ring are used. Winding are compressed under top and bottom clamping members with the help of tie rods. The axial end thrust under fault conditions is minimized by the suitable balance of the ampere-turns over the length of windings. In a case of the bigger transformer, the HV tapping leads are taken out from two positions to balance the short-circuit forces in a much better way.

Tank Construction:
All tank are made from mild steel sheet of adequate thickness with corrugated wall panel type radiators of pressed steel fin/cooling tube for heat dissipation.
All tanks are checked by magma flux, ultraviolet ray dies penetrating system to ensure that there is absolutely no leakage from any part of the tank.

Quality Finish Through Use Of Shotblasting Technology:
Tanks are shot blasted to remove mill and welding scale and then a primer coat is immediately applied to the exterior to eliminate rust formation.
After priming, all tanks receive a coat of intermediate paint and after pressure testing; they receive a final coat of high gloss paint applied by spray. This ensures high coverage helping to combat corrosion in an inaccessible place.
Request
Callback
Products & Services

Distribution Transformer 315 Kva

Distribution Transformer 315 Kva
  • Distribution Transformer 315 Kva
Get Best Quote
Approx. Price: Rs 4.5 Lakh / PieceGet Latest Price

Product Details:

Power Rating315kVA
Number of Phase3-Phase
Voltage Ratio11kV/433V
Cooling TypeOil Cooled
Winding MaterialCopper
StandardsIS-1180
BrandVirdi

The main process lines of the transformers are:

Core:
The core is made with laminated and low loss electrical steel sheets that are imported, grain oriented, cold rolled and sheets of high-grade steel. The cores are assembled in a manner that they reduce the noise caused by vibration; individual stamping is coated with insulation varnish which is resistant to heat and oil on both sides. The core is connected to the clamp which ensures that it is effectually earthed. The core legs are bounded with heavy-duty insulating tape. The yokes are rigidly and securely clamped between the folded steel channels. Clamps on top and bottom are firmly attached to each other by the means of tie rods. Tie rods serves the duel purpose of transferring the load from the bottom to the top clamps and securing the winding in place. This prevents tensile stress being setup in the core legs, which could adversely affect the iron losses.

Winding:
Transformer windings also known as 'Coils' are precisely designed to meet three basic requirements: thermal, mechanical and electrical. These windings wound concentrically and are cylinder shaped. Both H.V. L.V. type windings are wound with adequate securing and brazing tapes in order to get a sturdy, robust and self-supporting structure. It is provided with inter layer ducts which ensure low-temperature gradient between windings and oil so the hot spot temperature is kept to the minimum. This guarantees that the rate of insulation deterioration is lowered to attain high life expectancy.

Winding Connections:
Tapping and phase lead run in paper covered conductors. Adequate barriers are used to separate the phase leads from the tapping. Rigidly brazed tubes are used to maintain the required clearance from the coil to tank.
LV Leads, larger in cross-section, are usually sturdy and robust, where necessary supports are provided.

Insulation And Impregnation:
The principal component of insulation is insulating pre-compressed pressboard. The component like ring ducts dovetailed spacer; blocks etc. are put under compressing along with the coil assembly for preshrinking. The slight recovery in dimension after the preshrinking is compensated by providing additional insulation. This reduced the probability if coils getting loose during operation and also minimize the failure due to short circuit forces.

Short Circuit Capability:
In the order to prevent deformation under short-circuit forces; solid insulation end block and ring are used. Winding are compressed under top and bottom clamping members with the help of tie rods. The axial end thrust under fault conditions is minimized by the suitable balance of the ampere-turns over the length of windings. In a case of the bigger transformer, the HV tapping leads are taken out from two positions to balance the short-circuit forces in a much better way.

Tank Construction:
All tank are made from mild steel sheet of adequate thickness with corrugated wall panel type radiators of pressed steel fin/cooling tube for heat dissipation.
All tanks are checked by magma flux, ultraviolet ray dies penetrating system to ensure that there is absolutely no leakage from any part of the tank.

Quality Finish Through Use Of Shotblasting Technology:
Tanks are shot blasted to remove mill and welding scale and then a primer coat is immediately applied to the exterior to eliminate rust formation.
After priming, all tanks receive a coat of intermediate paint and after pressure testing; they receive a final coat of high gloss paint applied by spray. This ensures high coverage helping to combat corrosion in an inaccessible place.
Request
Callback
Products & Services

63 Kva Oil Cooled Distribution Transformer

63 Kva Oil Cooled Distribution Transformer
  • 63 Kva Oil Cooled Distribution Transformer
Get Best Quote
Approx. Price: Rs 1.05 Lakh / PieceGet Latest Price

Product Details:

Power Rating63kVA
Number of Phase3-Phase
Voltage Ratio11kV/433V
Cooling TypeONAN
Winding MaterialCopper
StandardsIS-1180
BrandVirdi
StandardIS-1180

The main process lines of the transformers are:

Core:
The core is made with laminated and low loss electrical steel sheets that are imported, grain oriented, cold rolled and sheets of high-grade steel. The cores are assembled in a manner that they reduce the noise caused by vibration; individual stamping is coated with insulation varnish which is resistant to heat and oil on both sides. The core is connected to the clamp which ensures that it is effectually earthed. The core legs are bounded with heavy-duty insulating tape. The yokes are rigidly and securely clamped between the folded steel channels. Clamps on top and bottom are firmly attached to each other by the means of tie rods. Tie rods serves the duel purpose of transferring the load from the bottom to the top clamps and securing the winding in place. This prevents tensile stress being setup in the core legs, which could adversely affect the iron losses.

Winding:
Transformer windings also known as 'Coils' are precisely designed to meet three basic requirements: thermal, mechanical and electrical. These windings wound concentrically and are cylinder shaped. Both H.V. L.V. type windings are wound with adequate securing and brazing tapes in order to get a sturdy, robust and self-supporting structure. It is provided with inter layer ducts which ensure low-temperature gradient between windings and oil so the hot spot temperature is kept to the minimum. This guarantees that the rate of insulation deterioration is lowered to attain high life expectancy.

Winding Connections:
Tapping and phase lead run in paper covered conductors. Adequate barriers are used to separate the phase leads from the tapping. Rigidly brazed tubes are used to maintain the required clearance from the coil to tank.
LV Leads, larger in cross-section, are usually sturdy and robust, where necessary supports are provided.

Insulation And Impregnation:
The principal component of insulation is insulating pre-compressed pressboard. The component like ring ducts dovetailed spacer; blocks etc. are put under compressing along with the coil assembly for preshrinking. The slight recovery in dimension after the preshrinking is compensated by providing additional insulation. This reduced the probability if coils getting loose during operation and also minimize the failure due to short circuit forces.

Short Circuit Capability:
In the order to prevent deformation under short-circuit forces; solid insulation end block and ring are used. Winding are compressed under top and bottom clamping members with the help of tie rods. The axial end thrust under fault conditions is minimized by the suitable balance of the ampere-turns over the length of windings. In a case of the bigger transformer, the HV tapping leads are taken out from two positions to balance the short-circuit forces in a much better way.

Tank Construction:
All tank are made from mild steel sheet of adequate thickness with corrugated wall panel type radiators of pressed steel fin/cooling tube for heat dissipation.
All tanks are checked by magma flux, ultraviolet ray dies penetrating system to ensure that there is absolutely no leakage from any part of the tank.

Quality Finish Through Use Of Shotblasting Technology:
Tanks are shot blasted to remove mill and welding scale and then a primer coat is immediately applied to the exterior to eliminate rust formation.
After priming, all tanks receive a coat of intermediate paint and after pressure testing; they receive a final coat of high gloss paint applied by spray. This ensures high coverage helping to combat corrosion in an inaccessible place.
Request
Callback
Products & Services

Projection Welder

Projection Welder
  • Projection Welder
Get Best Quote
Approx. Price: Rs 2.45 Lakh / UnitGet Latest Price

Product Details:

Rated Input Power380/415 Volts
Model Name/NumberProjection Welding Machine
MaterialAll
Automation GradeAutomatic
PhaseTwo Phase
Cooling Transformer TypeWater cooled

VIRDI Make Microprocessor Projection Welding MachineThree PhaseInput-380/415
Request
Callback
Products & Services

Projection Welding Machine

Projection Welding Machine
  • Projection Welding Machine
Get Best Quote
Approx. Price: Rs 2.45 Lakh / UnitGet Latest Price

Product Details:

Rated Input Power380/415 Volts
Model Name/NumberProjection Welding Machine
MaterialAll
Automation GradeAutomatic
PhaseTwo Phase
Cooling Transformer TypeWater cooled

VIRDI Make Microprocessor Projection Welding MachineThree PhaseInput-380/415
Request
Callback
Products & Services

CUT 80 Automatic Air Plasma Cutting Machine

CUT 80 Automatic Air Plasma Cutting Machine
  • CUT 80 Automatic Air Plasma Cutting Machine
Get Best Quote
Approx. Price: Rs 58,000 / UnitGet Latest Price

Product Details:

Max Cutting Thickness8-10 mm
Automation GradeSemi Automatic
Max Cutting Length1000-2000 mm
Max Cutting Speed1000-2000 mm/min
Max Cutting Width1000-2000 mm
PhaseThree phase
Cut80 cut

VIRDI make Air Plasma Cutting Machine.
An ISO 9001 : 2015 certified Company
1) Cut :- 40 to 160
2) Phase :- Single & Two Phase
3) Type - Inverter Type (IGBT)
4) Cutting Thickness :- 10mm to 50 mm
5) Accessories :- Torch, Air Filter, and Earthing Clamp.

A revolution in Cutting Systems, Inverter Based Portable Welding Machines delivers High Quality, surety and confimity to give you every reason to smile. The exactitude of qaulity standard IS 9001 : 2015 lies in its world class designing and engineering that took 3 Years for our engineers to master. The result, high performance innvoation that saves you more, ears you more and lets you enjoy all the more.
Request
Callback
Products & Services

Three Phase Constant Voltage Transformer

Three Phase Constant Voltage Transformer
  • Three Phase Constant Voltage Transformer
Get Best Quote
Approx. Price: Rs 22,500 / PieceGet Latest Price

Product Details:

PhaseThree
Power150 VA to 10 KVA
BrandVirdi
Capacity150 VA to 10 KVA
Accuracy Classavailable in all
Frequency50 Hz
Cooling TypeAir Cooled

Constant Voltage Transformers provides improved Voltage Regulation. It act as a current limiter. Constant Output Voltage irrespective of variation in Input Supply. It protects from Inrush, Harmonic and Noise. Constant Voltage Transformers are highly durable.
Request
Callback
Products & Services

Single phase Inverter type MIG Welding Machine

Single phase Inverter type MIG Welding Machine
  • Single phase Inverter type MIG Welding Machine
Get Best Quote
Approx. Price: Rs 42,000 / UnitGet Latest Price

Product Details:

BrandVIRDI
ModelVEWMIG01
Welding Current RangeInput 220/240 Volts
PhaseSingle Phase
CoolingFan Cooled
Efficiency50 Hz
TechnologyIGBT

The virdi welding machine has Capacities: 250 Amp - 600 Amp. This is the first time in India, you will find a welding machine having welders working at such high speed without any hang-ups. The virdi welding machines are of two types depending on the process used to cut hoses and tubes, Full contact and High speed.
Request
Callback
Products & Services

250 Kva Power Distribution Transformers

250 Kva Power Distribution Transformers
  • 250 Kva Power Distribution Transformers
Get Best Quote
Approx. Price: Rs 3.75 Lakh / PieceGet Latest Price
The main process lines of the transformers are:

Core:
The core is made with laminated and low loss electrical steel sheets that are imported, grain oriented, cold rolled and sheets of high-grade steel. The cores are assembled in a manner that they reduce the noise caused by vibration; individual stamping is coated with insulation varnish which is resistant to heat and oil on both sides. The core is connected to the clamp which ensures that it is effectually earthed. The core legs are bounded with heavy-duty insulating tape. The yokes are rigidly and securely clamped between the folded steel channels. Clamps on top and bottom are firmly attached to each other by the means of tie rods. Tie rods serves the duel purpose of transferring the load from the bottom to the top clamps and securing the winding in place. This prevents tensile stress being setup in the core legs, which could adversely affect the iron losses.

Winding:
Transformer windings also known as 'Coils' are precisely designed to meet three basic requirements: thermal, mechanical and electrical. These windings wound concentrically and are cylinder shaped. Both H.V. L.V. type windings are wound with adequate securing and brazing tapes in order to get a sturdy, robust and self-supporting structure. It is provided with inter layer ducts which ensure low-temperature gradient between windings and oil so the hot spot temperature is kept to the minimum. This guarantees that the rate of insulation deterioration is lowered to attain high life expectancy.

Winding Connections:
Tapping and phase lead run in paper covered conductors. Adequate barriers are used to separate the phase leads from the tapping. Rigidly brazed tubes are used to maintain the required clearance from the coil to tank.
LV Leads, larger in cross-section, are usually sturdy and robust, where necessary supports are provided.

Insulation And Impregnation:
The principal component of insulation is insulating pre-compressed pressboard. The component like ring ducts dovetailed spacer; blocks etc. are put under compressing along with the coil assembly for preshrinking. The slight recovery in dimension after the preshrinking is compensated by providing additional insulation. This reduced the probability if coils getting loose during operation and also minimize the failure due to short circuit forces.

Short Circuit Capability:
In the order to prevent deformation under short-circuit forces; solid insulation end block and ring are used. Winding are compressed under top and bottom clamping members with the help of tie rods. The axial end thrust under fault conditions is minimized by the suitable balance of the ampere-turns over the length of windings. In a case of the bigger transformer, the HV tapping leads are taken out from two positions to balance the short-circuit forces in a much better way.

Tank Construction:
All tank are made from mild steel sheet of adequate thickness with corrugated wall panel type radiators of pressed steel fin/cooling tube for heat dissipation.
All tanks are checked by magma flux, ultraviolet ray dies penetrating system to ensure that there is absolutely no leakage from any part of the tank.

Quality Finish Through Use Of Shotblasting Technology:
Tanks are shot blasted to remove mill and welding scale and then a primer coat is immediately applied to the exterior to eliminate rust formation.
After priming, all tanks receive a coat of intermediate paint and after pressure testing; they receive a final coat of high gloss paint applied by spray. This ensures high coverage helping to combat corrosion in an inaccessible place.
Request
Callback
Products & Services

2000 Kva Power Transformer

2000 Kva Power Transformer
  • 2000 Kva Power Transformer
Get Best Quote
Approx. Price: Rs 20.25 Lakh / PieceGet Latest Price

Product Details:

Power Rating2000 KVA
Number of Phase3-Phase
Voltage Ratio11kV/433V
Cooling TypeONAN
Winding MaterialCopper
StandardsIS-1180
BrandVirdi

Each and every component of the OLTCTransformer is manufactured and assembled with precision and utmost care. The main process lines of the transformers are:

Core:
The core is made with laminated and low loss electrical steel sheets that are imported, grain oriented, cold rolled and sheets of high-grade steel. The cores are assembled in a manner that they reduce the noise caused by vibration; individual stamping is coated with insulation varnish which is resistant to heat and oil on both sides. The core is connected to the clamp which ensures that it is effectually earthed. The core legs are bounded with heavy-duty insulating tape. The yokes are rigidly and securely clamped between the folded steel channels. Clamps on top and bottom are firmly attached to each other by the means of tie rods. Tie rods serves the duel purpose of transferring the load from the bottom to the top clamps and securing the winding in place. This prevents tensile stress being setup in the core legs, which could adversely affect the iron losses.

Winding:
Transformer windings also known as 'Coils' are precisely designed to meet three basic requirements: thermal, mechanical and electrical. These windings wound concentrically and are cylinder shaped. Both H.V. L.V. type windings are wound with adequate securing and brazing tapes in order to get a sturdy, robust and self-supporting structure. It is provided with inter layer ducts which ensure low-temperature gradient between windings and oil so the hot spot temperature is kept to the minimum. This guarantees that the rate of insulation deterioration is lowered to attain high life expectancy.

Winding Connections:
Tapping and phase lead run in paper covered conductors. Adequate barriers are used to separate the phase leads from the tapping. Rigidly brazed tubes are used to maintain the required clearance from the coil to tank.
LV Leads, larger in cross-section, are usually sturdy and robust, where necessary supports are provided.

Insulation And Impregnation:
The principal component of insulation is insulating pre-compressed pressboard. The component like ring ducts dovetailed spacer; blocks etc. are put under compressing along with the coil assembly for preshrinking. The slight recovery in dimension after the preshrinking is compensated by providing additional insulation. This reduced the probability if coils getting loose during operation and also minimize the failure due to short circuit forces.

Short Circuit Capability:
In the order to prevent deformation under short-circuit forces; solid insulation end block and ring are used. Winding are compressed under top and bottom clamping members with the help of tie rods. The axial end thrust under fault conditions is minimized by the suitable balance of the ampere-turns over the length of windings. In a case of the bigger transformer, the HV tapping leads are taken out from two positions to balance the short-circuit forces in a much better way.

Tank Construction:
All tank are made from mild steel sheet of adequate thickness with corrugated wall panel type radiators of pressed steel fin/cooling tube for heat dissipation.
All tanks are checked by magma flux, ultraviolet ray dies penetrating system to ensure that there is absolutely no leakage from any part of the tank.

Quality Finish Through Use Of Shotblasting Technology:
Tanks are shot blasted to remove mill and welding scale and then a primer coat is immediately applied to the exterior to eliminate rust formation.
After priming, all tanks receive a coat of intermediate paint and after pressure testing; they receive a final coat of high gloss paint applied by spray. This ensures high coverage helping to combat corrosion in an inaccessible place.
Request
Callback
Products & Services

Cut 100 Plasma Cutting Machines

Cut 100 Plasma Cutting Machines
  • Cut 100 Plasma Cutting Machines
Get Best Quote
Approx. Price: Rs 68,500 / UnitGet Latest Price

Product Details:

Max Cutting Thickness15-20 mm
Automation GradeSemi Automatic
Max Cutting Length1000-2000 mm
Max Cutting Speed1000-2000 mm/min
Max Cutting Width1000-2000 mm
PhaseThree phase
Cut100 Cut

VIRDI make Air Plasma Cutting Machine.
An ISO 9001 : 2015 certified Company
1) Cut :- 40 to 160
2) Phase :- Single & Two Phase
3) Type - Inverter Type (IGBT)
4) Cutting Thickness :- 10mm to 50 mm
5) Accessories :- Torch, Air Filter, and Earthing Clamp.

A revolution in Cutting Systems, Inverter Based Portable Welding Machines delivers High Quality, surety and confimity to give you every reason to smile. The exactitude of qaulity standard IS 9001 : 2015 lies in its world class designing and engineering that took 3 Years for our engineers to master. The result, high performance innvoation that saves you more, ears you more and lets you enjoy all the more.
Request
Callback
Products & Services

Virdi Constant Voltage Transformer

Approx. Price: Rs 22,500 / PieceGet Latest Price

Product Details:

PhaseThree
Power150 VA to 10 KVA
BrandVirdi
Capacity150 VA to 10 KVA
Accuracy Classavailable in all
Frequency50 Hz
Cooling TypeAir Cooled

Constant Voltage Transformers provides improved Voltage Regulation. It act as a current limiter. Constant Output Voltage irrespective of variation in Input Supply. It protects from Inrush, Harmonic and Noise. Constant Voltage Transformers are highly durable.
Request
Callback
Get Best Quote
Products & Services
X

Product Videos

Watch More Videos

Explore More Product

View All Product


Reviews & Rating

3.9/5

★★★★★★★★★★

Reviewed by 36 Users

  • 5★50%
  • 4★8%
  • 3★8%
  • 2★9%
  • 1★25%
  • User Satisfaction
  • Response50%
  • Quality     83%
  • Delivery   100%

Most Relevant Reviews

K
★★★★★★★★★★
20-May-21
King King
China
Product Name : Arc Welding Machines
for our efficient communication . please your whatsapp number ? thanks . my whatsapp number 8613267147616 .
Response
Quality
Delivery
N
★★★★★★★★★★
19-December-20
Nilesh
Giridih, Jharkhand
Quality
Delivery
reviewImg1
H
★★★★★★★★★★
15-June-22
Hans Matthiesen
Rewalsar, Himachal Pradesh
this company do NOT like / use email

View More Reviews




Reach Us
Gurmeet Virdi (CEO)
Virdi Electric Works Private Limited
C-21, Sector 63, Noida
Gautam Budh Nagar - 201301, Uttar Pradesh, India


Call Us


Send E-mail